Skip to content

fix(curtain): parse curtain advertisements as pySwitchbot does (pySwitchbot 3.8.2) - #364

Merged
donavanbecker merged 1 commit into
latestfrom
fix/curtain-advertisement
Nov 16, 2026
Merged

donavanbecker merged 1 commit into
latestfrom
fix/curtain-advertisement

Conversation

@donavanbecker

Copy link
Copy Markdown
Contributor

Ports pySwitchbot 3.8.2, and fixes curtain advertisement parsing that turned up while checking it.

pySwitchbot 3.8.2

The release has one behaviour change, #614. pySwitchbot gave a device that was first heard without service data the caller's fallback model, then kept that model even after a later advertisement identified the device. node-switchbot doesn't need the fix: it ignores advertisements without service data, so it never assigns a fallback model. A new test runs pySwitchbot's #614 fixtures through the scanner. The first advertisement is ignored and the second identifies a Curtain 3.

The rest of the release is dependency and CI bumps, which don't apply here.

Curtain advertisement fixes

Running those fixtures showed that node-switchbot's curtain parsing didn't match pySwitchbot's process_wocurtain or the SwitchBotAPI-BLE curtain docs:

Field Before Now
inMotion byte 1 bit 6 (the calibration bit) byte 3 bit 7
calibration byte 1 bit 5 (unused) byte 1 bit 6
lightLevel byte 4 & 0x7F high nibble of byte 4 (1–10)
deviceChain byte 5 & 0x03 byte 4 & 0x07
Source service data only manufacturer data when present (mfr[8:11]), service data otherwise
Battery service data mfr[12] on Curtain 3, service data otherwise

The parser is now src/utils/curtain-advertisement.ts (parseCurtainAdvertisement), alongside the lock and sensor parsers.

The scanner also accepts the legacy 0x0D00 service UUID that pySwitchbot accepts. It already accepted 000d, which is how the docs write it byte-wise; that spelling still works.

Position meaning is unchanged: 0 = open, 100 = closed, as the curtain reports it. pySwitchbot reverses it by default, but homebridge-switchbot and other consumers already convert. The tests use pySwitchbot's fixtures, with positions written as 100 minus pySwitchbot's.

Tests

  • test/utils/curtain-advertisement.test.ts: pySwitchbot's curtain fixtures (Curtain, firmware 6, Curtain 3), the motion bit, the #614 sequence and the legacy UUID.
  • test/types/model-identities.test.ts: the Curtain 3 [ test had pinned the old bits and a 5-byte payload. It now uses the documented layout.

Build, test (526) and lint pass. This hasn't been tested on a real curtain.

Consumers: no breaking changes. homebridge-switchbot reads only position, so it needs no follow-up; it picks up the fix through the automatic dependency PR.


Generated by Claude Code

Port of pySwitchbot's process_wocurtain, found while porting pySwitchbot 3.8.2:

- read the state from the manufacturer data when present (mfr[8:11]), and the
  Curtain 3 battery from mfr[12]; fall back to the service data
- moving is bit 7 of the position byte, not the calibration bit
- calibrated is bit 6 of byte 1, not bit 5
- light level is the high nibble of byte 4 and the device chain its low 3 bits
- accept the legacy 0x0D00 service UUID that pySwitchbot accepts

The position stays as the curtain reports it (0 open, 100 closed).

pySwitchbot 3.8.2 (#614) needs no port: node-switchbot never assigns a model to an
advertisement without service data. A test pins that with pySwitchbot's fixtures.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01TYWa2RXoWsaUTWh76oNv8s
@donavanbecker donavanbecker added the patch label Nov 16, 2026 — with Claude
@donavanbecker
donavanbecker merged commit 8e2b5f9 into latest Nov 16, 2026
3 checks passed
@donavanbecker
donavanbecker deleted the fix/curtain-advertisement branch November 16, 2026 04:59