[Bug]: A thread stopped by a usage limit is labelled Failed, indistinguishable from a crash #10545
Look at the thread's row in the sidebar (web) or the thread list (mobile), and at the red banner above the timeline.
Expected behavior
A thread that stopped because the account is out of quota reads as waiting, not broken: the row says something like Limited in the amber tone the other wait states use (Approval, Woke), and the thread banner is a warning, not an error. A user scanning ten threads should tell "this one hit the limit, it will work again at 9:20" from "this one crashed" without opening each.
Actual behavior
The row says Failed in red and the banner is the red error banner, identical to a provider crash or a transport error. Since #8358 and #10321 a usage-limit stop is deliberately a failed turn with a visible message, which is right for the turn state, but the clients have no way to tell the two failures apart: OrchestrationSession carries only lastError (a string) and status: "error", so resolveSidebarThreadStatus (apps/web/src/components/Sidebar.logic.ts) and resolveThreadListV2Status (apps/mobile/src/features/threads/threadListV2.ts) both map every errored session to failed. The adapters already know the difference: the Claude adapter emits the limit as a runtime.error whose payload has a class slot (provider_error today), and #10473 does the same for Codex.
The thread on the left stopped on a limit; the row and banner call it a failure:
Suggested shape, keeping the failed-turn model: add usage_limit to the runtime error class the adapters already send, carry it onto the session as lastErrorClass beside lastError, and let the web sidebar, the mobile list, and the thread banner read it. No change to turn state, retries, or settlement.
Related: #7314 (subagent status stays red after a limit recovery) is the same blindness one level down; #9012 offers the snooze from the same signal.
Thanks for the tight write-up and screenshots — this checks out on current main.
A usage-limit stop is supposed to be a failed turn with a readable message (#8358, #10321). That part is fine. The clients then have no structured way to tell it apart from a crash:
Claude/Codex emit runtime.error with class: "provider_error" (ClaudeAdapter.emitRuntimeError, same slot in CodexAdapter). RuntimeErrorClass has no usage_limit today.
Ingestion copies only payload.message onto OrchestrationSession.lastError and sets status: "error". There is no lastErrorClass.
resolveSidebarThreadStatus and resolveThreadListV2Status map every errored session to failed, so the web row and the mobile list both say Failed in red.
ThreadErrorBanner is hard-coded variant="error" even though Alert already has a warning tone.
So a scan of ten threads cannot tell “this one hit the window, retry after reset” from “this one crashed.”
Not a duplicate of #7314 (same blindness one level down, on subagents) or of #10544 / #10472 (those are about the sentence, not the list/banner classification). Complementary to #9012 (snooze from the reset signal). Do not reopen the #9236 approach of treating the turn as cancelled/warning-only.
Suggested fix, matching the report: add usage_limit to the runtime error class the adapters already send, persist it on the session as lastErrorClass beside lastError (contract + projection_thread_sessions column), and let the web sidebar, mobile list, and thread banner (warning, not error) read it as an amber wait state — Limited, same family as Approval / Woke. No change to turn state, retries, or settlement. String-matching lastError is the wrong path.
Accepting as a minor classification bug. Implementation can land independently of #10473 / #10546; those PRs should emit the new class once it exists.
Thanks. The PR is in progress on that exact shape, with one trim: no new field on turn.completed. Both adapters emit the classed runtime.error before the failed completion, so ingestion carries lastErrorClass forward on the failed turn.completed and clears it on the transition to ready, the same way lastError flows today. Once it lands, #10473 and #10546 each gain the one line that sets the class on their limit error.
Activity
juliusmarminge commentedon Sep 7, 2026
Thanks for the tight write-up and screenshots — this checks out on current main.
A usage-limit stop is supposed to be a failed turn with a readable message (#8358, #10321). That part is fine. The clients then have no structured way to tell it apart from a crash:
runtime.errorwithclass: "provider_error"(ClaudeAdapter.emitRuntimeError, same slot inCodexAdapter).RuntimeErrorClasshas nousage_limittoday.payload.messageontoOrchestrationSession.lastErrorand setsstatus: "error". There is nolastErrorClass.resolveSidebarThreadStatusandresolveThreadListV2Statusmap every errored session tofailed, so the web row and the mobile list both say Failed in red.ThreadErrorBanneris hard-codedvariant="error"even thoughAlertalready has a warning tone.So a scan of ten threads cannot tell “this one hit the window, retry after reset” from “this one crashed.”
Not a duplicate of #7314 (same blindness one level down, on subagents) or of #10544 / #10472 (those are about the sentence, not the list/banner classification). Complementary to #9012 (snooze from the reset signal). Do not reopen the #9236 approach of treating the turn as cancelled/warning-only.
Suggested fix, matching the report: add
usage_limitto the runtime error class the adapters already send, persist it on the session aslastErrorClassbesidelastError(contract +projection_thread_sessionscolumn), and let the web sidebar, mobile list, and thread banner (warning, not error) read it as an amber wait state — Limited, same family as Approval / Woke. No change to turn state, retries, or settlement. String-matchinglastErroris the wrong path.Accepting as a minor classification bug. Implementation can land independently of #10473 / #10546; those PRs should emit the new class once it exists.
vitalyiegorov commentedon Sep 7, 2026
Thanks. The PR is in progress on that exact shape, with one trim: no new field on
turn.completed. Both adapters emit the classedruntime.errorbefore the failed completion, so ingestion carrieslastErrorClassforward on the failedturn.completedand clears it on the transition to ready, the same waylastErrorflows today. Once it lands, #10473 and #10546 each gain the one line that sets the class on their limit error.vitalyiegorov commentedon Sep 7, 2026
PR: #10550.