You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
driverAlign() ignores gain sign, always "MOT: Success: 3" #386
I try to get current sensing working on a custom STM32G431CUBx board. With low side current sensing based on three shunt resistors and the internal op amps.
So far the motor spins fine without current sensing.
Also I tested the CS with a DC current on each phase to calibrate the Gain and verify the hardware -> all ok.
But the dirverAlign() funktion always returns MOT: Success: 3
I set the Gain to "70" and stepp thru the calibration
ab_ratio and ac_ratio are about ~2
at the end of the function all gains are <0 ->MOT: Success: 3
But if I invert the gain to "-70"
the currents are inverted and the ratio is ~2 so:
this changes the gains again:
-> Success: 3
So something is wrong I'm not where the problem is, my gain should be positive since if I disconnect the motor and input a DC current to on phase the ADC value goes up. To test this I just enabled the low side mosfet and hocked up a second power supply ind constant current mode.
Also my Currents are off by a factor of 10 my opamp gain is 7 but then the measured current values are by 10 to high (but this is probably a different problem)
The DC supply is set to 1A and the ADC values go up by like ~80 digits my shunt resistor is 0.01 Ohms.
changed the title [-]driverAlign() ignores gain sign allways "MOT: Success: 3"[/-][+]driverAlign() ignores gain sign always "MOT: Success: 3"[/+]on Feb 29, 2024
changed the title [-]driverAlign() ignores gain sign always "MOT: Success: 3"[/-][+]driverAlign() ignores gain sign, always "MOT: Success: 3"[/+]on Feb 29, 2024
I agree we should change the code to only return 3 (or 4) if the gains were actually inverted compared to the user supplied setting. It's not a hard fix, so could be in the next release.
Thank you, it is a little bit confusing and I was not sure if the output was intended.
It would help, if you change the sign of the gain it should somehow influence the outcome downstream ...
Hi guys,
The new current sense init #422 is in the release v2.3.4.
It has several new features and that make it easier to use and has the suggested modification. :D
The new code returns 3 or 4 only if the gains are actually inverted.
Activity
[-]driverAlign() ignores gain sign allways "MOT: Success: 3"[/-][+]driverAlign() ignores gain sign always "MOT: Success: 3"[/+][-]driverAlign() ignores gain sign always "MOT: Success: 3"[/-][+]driverAlign() ignores gain sign, always "MOT: Success: 3"[/+]Candas1 commentedon Feb 29, 2024
Hi,
This is how the code works.
It will just give you success 3 if the gains are negative, even if it's correct.
That's not a problem but it could be improved.
runger1101001 commentedon Feb 29, 2024
I agree we should change the code to only return 3 (or 4) if the gains were actually inverted compared to the user supplied setting. It's not a hard fix, so could be in the next release.
4ndreas commentedon Feb 29, 2024
Thank you, it is a little bit confusing and I was not sure if the output was intended.
It would help, if you change the sign of the gain it should somehow influence the outcome downstream ...
askuric commentedon Jul 22, 2024
Hi guys,
The new current sense init #422 is in the release v2.3.4.
It has several new features and that make it easier to use and has the suggested modification. :D
The new code returns 3 or 4 only if the gains are actually inverted.